Sindbad~EG File Manager

Current Path : /usr/local/share/doc/db18/programmer_reference/
Upload File :
Current File : /usr/local/share/doc/db18/programmer_reference/program_cache.html

<?xml version="1.0" encoding="UTF-8" standalone="no"?>
<!DOCTYPE html PUBLIC "-//W3C//DTD XHTML 1.0 Transitional//EN" "http://www.w3.org/TR/xhtml1/DTD/xhtml1-transitional.dtd">
<html xmlns="http://www.w3.org/1999/xhtml">
  <head>
    <meta http-equiv="Content-Type" content="text/html; charset=UTF-8" />
    <title>Disk drive caches</title>
    <link rel="stylesheet" href="gettingStarted.css" type="text/css" />
    <meta name="generator" content="DocBook XSL Stylesheets V1.73.2" />
    <link rel="start" href="index.html" title="Berkeley DB Programmer's Reference Guide" />
    <link rel="up" href="program.html" title="Chapter 16.  Programmer Notes" />
    <link rel="prev" href="program_ram.html" title="Memory-only or Flash configurations" />
    <link rel="next" href="program_copy.html" title="Copying or moving databases" />
  </head>
  <body>
    <div xmlns="" class="navheader">
      <div class="libver">
        <p>Library Version 18.1.40</p>
      </div>
      <table width="100%" summary="Navigation header">
        <tr>
          <th colspan="3" align="center">Disk drive caches</th>
        </tr>
        <tr>
          <td width="20%" align="left"><a accesskey="p" href="program_ram.html">Prev</a> </td>
          <th width="60%" align="center">Chapter 16.  Programmer Notes </th>
          <td width="20%" align="right"> <a accesskey="n" href="program_copy.html">Next</a></td>
        </tr>
      </table>
      <hr />
    </div>
    <div class="sect1" lang="en" xml:lang="en">
      <div class="titlepage">
        <div>
          <div>
            <h2 class="title" style="clear: both"><a id="program_cache"></a>Disk drive caches</h2>
          </div>
        </div>
      </div>
      <p>
        Many disk drives contain onboard caches. Some of these
        drives include battery-backup or other functionality that
        guarantees that all cached data will be completely written if
        the power fails. These drives can offer substantial
        performance improvements over drives without caching support.
        However, some caching drives rely on capacitors or other
        mechanisms that guarantee only that the write of the current
        sector will complete. These drives can endanger your database
        and potentially cause corruption of your data.
    </p>
      <p>
        To avoid losing your data, make sure the caching on your
        disk drives is properly configured so the drive will never
        report that data has been written unless the data is
        guaranteed to be written in the face of a power failure. Many
        times, this means that write-caching on the disk drive must be
        disabled.
    </p>
    </div>
    <div class="navfooter">
      <hr />
      <table width="100%" summary="Navigation footer">
        <tr>
          <td width="40%" align="left"><a accesskey="p" href="program_ram.html">Prev</a> </td>
          <td width="20%" align="center">
            <a accesskey="u" href="program.html">Up</a>
          </td>
          <td width="40%" align="right"> <a accesskey="n" href="program_copy.html">Next</a></td>
        </tr>
        <tr>
          <td width="40%" align="left" valign="top">Memory-only or Flash
        configurations </td>
          <td width="20%" align="center">
            <a accesskey="h" href="index.html">Home</a>
          </td>
          <td width="40%" align="right" valign="top"> Copying or moving databases</td>
        </tr>
      </table>
    </div>
  </body>
</html>

Sindbad File Manager Version 1.0, Coded By Sindbad EG ~ The Terrorists